Quantcast
Channel: Modicon / Telemecanique / Schneider Electric Latest Topics
Viewing all 446 articles
Browse latest View live

Up-grade Premium to M580

$
0
0

Hi,

 

I am planning to upgrade a premium PLC to M580, I have the program uploaded from existing premium PLC. I tried to convert the program by using UMAC but lof of errors happening, can any one help on this?

Regards

Sandeep


modicon

$
0
0

I have a modicn tsx that runs a vacuum former, the battery light was on, changed the battery but now I have ter and err lights flashing and the magelis controller is saying no program writing 

PM5000 series and Modbus

$
0
0

Hello,

I would like to receive data from our PM5100 Power Meter via Modbus using a Omron PLC. I am sure that it will use Modbus RTU as I have controlled Altivar Inverters using this system. Does anyone know where I can access the Modbus Registry for this Meter? I really want to log KWH usage.

 

Regards 

 

Peter 

EcoStruxure Machine Expert-Installing help files

$
0
0

Hello everyone,

I installed V1.2 by using the installer to download the files and then install offline. The program installed fine and works well but I have not been able to install the help files.

I have the files downloaded and following instructions I started the installer and clicked on Modify installed software Customize Version>Help files, but then I get a blank page.

Anyone knows how to?

 

Thanks

 

 

help.PNG

modbus register address

$
0
0

hi guys

i am using my Schneider m221 plc  but

facing this below problem.

how can write modbus address  i am trying below register data address but not accept this register data  address example i write

%MW0:=16#10001

%MW1:=16#10002

%MW2:=16#10003

%MW3:=16#10004

so guys how can write this register address can me  share one example so i understand. also share read var setting .

ObjType:

FristObj:

Quantity:

IndexData:

Thanks

modbus1111.PNG

Shift bit somachine

$
0
0

Hello,

Maybe somebody know. I am using variable, which address is %MW100. I am trying shifting register bit. I made video. The Variable changed, but variables, which address is %MX100.0 ... %MX100.7  does not change. Why?

ScreenRecorderProject2.mp4

Export symbols from SoMachine Motion for import to OPC server

$
0
0

This is hard work!

I've installed the CODESYS OPC Server V3 in the hope of using it to communicate with my Schneider PacDrive LMC. Apparently the PLC doesn't support OPC tag browsing so I need to export the symbols from the SoMachine Motion project file in a format that the OPC server can use.

I've got the Symbol Configuration panel open and can see the symbol tree.

What do I do next?

help TSX 47 30 Telemecanique

$
0
0

Hi,

I have an old TSX 47 30 that has an I / O fault (red led on) green led on run and plc stopped. I'm writing to see if you can help me to establish communication and achieve the download of the program. I do not have the communication cable or the PL7-3 software under OS 2. So far I have done searches on the schneider page, forums and all the links are lost or deactivated. I have read your answers in plc of the same series and I observe that a converter rs 232 to current loop is needed. In this case here in Venezuela it is difficult to get this converter, however I have observed the black box model 232 CL-E, CL050A and I think it can be useful. I also have an old toshiba laptop with windows xp with a native rs 232 port to avoid another converter and I could make the connection cable DB25-DB9 to the PLC. Now I would miss the procedure to make an OS / 2 bios and get the software or make a virtual machine in which case I require the appropriate software .. thanks for your help


PL7-2 installing

$
0
0
Hi Everybody. I have problem with install a PL7-2 software for programming TSX17 First installing a user interface from floppy is OK When I start installing a program then apperars error Fatal Error :214 C:\XDOSSYS\HLP\*.* What is the reason for this? OP system is Win98 and laptop is PII IBM ThinkPad I tryed also Win95 and other PC´s - result is same. I did everything like in this help manual Greetings Pertti PL7_2_V51.doc

TSX PSY 3610 power supply module alarm contact open

$
0
0

Hi,

I have a modicon premium plc rack with TSX PSY 3610 power supply module. The psy 3610 power supply has an alarm contact and it is used in a loop to energize a hard ware relay for 24VDC supply to the DO module FTA boards. There is a safety button in parallel to the alarm contact so that during startup we can press this button, energies DO module loops and all IO faults cleared and power supply alarm contact latches

The problem is that this power supply alarm contact remains always open even when IO report no faults. The PLC has MAST task only and it is running with no faults. If I jumper the alarm contact all the IO's are healthy .

tried changing the power supply and DO modules. no hope. please help.

modicon 484 automate

$
0
0

Hi all;

we have  modicon 484 automate, and we want to read/ record and make a backup  of  the exciting  program from CPU ,  but ower console P180 is Breakdown
I would like to know if there are is  solution on how to read  the program using compteur and what is the   software and cables required.  

Modicon 484

$
0
0

Hi,

We have a Modicon 484 automate in our plant, and we want to read/ record and make a backup of the exciting program from CPU, but our console programmer P180 is out of service.
I would like to know if there is any solution to communicate witch the CPU using a computer and what software/ cables we need to do that.

thanks;

Magelis GTO Panel HMIGTO5310

$
0
0

Hi everyone. I am quite noob in regard of PLC but would like to ask for your advice anyway)))

Is there any way I can connect throught the Ethernet port to HMIGTO5310 panel and operate it remotely from the PC?

(Something like Remote Desktop Connection in Windows or similar, or independenly)

If yes which software I have to use?

Will Vijeo Designer help me much? :)

Thanks a lot!

Sergey

PL7 Download

$
0
0

Hello, 

Anyone know where I can get a copy of PL7 Software. I have a Modicon TSX Premium I need to access but I can find the software anywhere online. Any help would be greatly appreciated.

Thank you. 

M221C40R + TM3AQ2 analog output

$
0
0

Hi guys,

I'm in another project with another brand on PLC and this time I thick I hit a pretty solid wall.

Long story short, I need to change a -10 +10v signal send to a DC motor drive based on a "recipe" selected with a 10 positions camswitch.

I've never programmed schneider PLC, except the zélio one who are pretty simple to understand.
Apparently Modicon are much more complex to program with the knowledge I have.
Is there documentation available somewhere I can use to understand how to code analog output.


M340 Ethernet IP

$
0
0

I am 100% new to Schneider PLCs, we have a project come in where the customer wants to use a M340 PLC to communicate to several Festo devices, CPX valve island and Simple Servo drives. The Festo equipment is capable of Ethernet IP which we would use for a Rockwell Solution. Is Ethernet IP possible with M340 PLC and associated communication cards?

Thanks for any input

shift array with struct

$
0
0

Is it possible shift data array. I have

Array_ret:                                    ARRAY[0..10] OF test;   

and

TYPE tests :
STRUCT
	TinFoil:		BOOL;
	InFrame:		BOOL;
END_STRUCT
END_TYPE

I want shift all one time time Array_rest[0] information to Array_rest[1]. Array_rest[1] to Array_rest[2] and...

Is it possible?

anybody who may read out telemecanique cartridge

$
0
0

Hello all,

is anybody out there who may read out a program that is stored on a telemecanique cartridge (more or less of 1993)? Program is still running on a TSX 47 40, but have an identical second cartridge. I would send it to him/her even if international post and do not necessarily require the cartridge back.

Would be great to have the program as a text file / pdf / hardcopy. Any help appreciated!!

Best regards

Stefan

cartridge.jpg

SQL writing statement

$
0
0
Hi,
I need a code to write in SQL only when the variable changes its value. Can someone help me?

Thanks

M241 Send Email

$
0
0

Hi,

I would like via M241 Schneider PLC send external but the email server is not in the same IP Range address (ex: Microsoft Exchange 365 or hotmail).

I tryed with library email handling (Ecostruxure Machine expert). Do you have an example with external email configuration.

Thank you very much.

Viewing all 446 articles
Browse latest View live