0
0

Hi there. 

 

Im after some help with the replacement of a TSX 17 PLC. Unfortunately we do not have a copy of the program but it is a very vital machine. It has been running well for 25+ years.

It seems that the PLC unit is dead. 24v in but no lights or anything on at all. 

We are hoping to source a direct replacement. We are also hoping that the EEPROM holds the program. 

Is  there anything we should be aware of? Or anything we should do to ensure a smooth changeover?

 

Thanks


Unity Pro LD Column Width?

$
0
0

Hi All

Been trying to change the column width of an LD Section (is this possible?) Currently there are 11 columns - I would like a few more if possible

In Tools -> Project Settings -> Program -> LD there is an option 'Number of Columns' - whatever I try and change it to it sticks at 11

At the same location there is a setting for 'Cell Width' - Single, Double, Triple which works fine

Circles again.....:-(

Regards

No Alarm name in HISTORY ALRM panel for Magelis XBT-N400

$
0
0

Hi,

In Vijeo-Designer Lite, i configured a dialog table to exchange data between the PLC (ScadaPack 32) and the operator interface (XBT-N400). I added the alarm table function in this dialog table. 

The alarm name and the alarm panels has the same name. Th  Log element in the Alarm Settings tab is enable. I included a static text on the alarm panel for each alarm.  It was necessary to add this static text on the alarm panel because without it, even the live alarms were showing up without any names or description.

When an alarm is generated, the live alarm shows the static text but the historical alarm in the alarm history panel (HISTORY ALRM) does not show the alarm name or the static text.

Attached is the configuration file.

Thanks in advance for the assistance.

1.    

 

 

CGCLfinal_07032019.dop

Screenshots of configuration.docx

SoMachine, Web Visu download csv file

$
0
0

Hello

I have a M251, running a webvisu. I have created a program to create a test report to a *csv file and store it on sd card.

What I want to do next is to allow the user to download the * csv from the webvisu and not via ftp client like Filezilla.

On codesys forums I see there are file up and download options for buttons (click behaviour) but they are not available in Somachine 4.3.

One option I am considering is using the TCP server and steam the file manually from a button click.

I dont want a ftp client as now the customer will then needsoftware on his pc, this plc is a portable test system and will be controlled by many different pc's.

Is anyone aware of a simpler way to do this?

Magelis xbt p021010

$
0
0
Hello everyone. equipment: I have an old Telemeqanique Premium as a PLC; and have a Magelis xbt p021010 as a scada. (it is old because, Nowadays I could not find any components for it) situation: For now it controls only 1 workshop. What I want was to control my second workshop with same PLC and Scada. Hence, I programmed the PLC [ just added 2 rungs :) ]. And it works fine. But in this stage I have to change timings from PLC. When it comes to programing Scada. I could not find my old version program, but find XBTL1000 V4.5. problem: When I tried to import from Scada, it returned "This is not a XBT L-1000 file" error. When I tried to open from 8_8_8_U.DOP file, it returned "This is not a XBT L-1000 file" error. solution: 1- I wrote all the pages from Scada to a scratch Paper. 2- I created a new DOP file with pages as in the Paper and named as 8_8_8_U.DOP. 3- I compared two files (the old DOP file and the new DOP file (new one was without any links MWs configured or had alarms in it)) hex by hex with free the program Hex Editor Neo. There I made "copy/paste" the differeneces as mouch as I could. In the end, I had a new DOP file exact copy of old DOP file (not exactly hexwise, but contentwise) with all the pages, link, alarms etc. 4- While editing I saw on the old file that SCADA is chosen as p022010. Hence I implement my new file as p022010 again. 5- Lastly I combined old three pages to two pages. And add a new third page as my workshop 2 timings. For workshop 2 no alarm is required, so i did not touch the alarm pages. question: Although my new file opens with new XBT program successfully, can I upload my new file to scada? Will it work although it was maden by the new versioned program. attention: Please read the "problem" part again. I do not wish to stop my workshop 1. Please advise. 8_8_8_U_oldfile.zip 8_8_8_U_newfile.zip

''INVISIBLE'' buttons in PROFACE

$
0
0

Hello, 

I am doing PROFACE HMI touch screen projects, and I recently came up with an problem. I am using GP-PRO EX software to program and then later I would transfer the project to my PROFACE GP-4501TW. Now I came up with a problem, on one page there is no buttons on labels that I had written, But when I check it on the software its still there. So, its like I have buttons programmed but not showing on the touch screen! Also I can touch the buttons and it beeps and using WINDLDR I had found that the button works but that its somewhat hidden. Later I found out that LAMP FEATURE was turned on that caused the ''invisible button'' to happen. So, when I turned LAMP FEATURE OFF the buttons would return on the touch screen. I tried Preview, Simulation mode but all that showed the buttons. I have attached he pics below

THANK YOU

A COMPANY  

SAM_3951.JPG

SAM_3952.JPG

m221 input combination

$
0
0

Hello all! I'm new to programming and I would have some help. I have a Schneider m221 plc and i use somachine basic for programming. The question is the following. How can i make calculations like combinations of 7 take 5? and here I am strictly referring to the IN. It can be made simple with NO and NC contacts, but from many program lines it does not move anymore, and the work is colossal. Can a user defined block be able to calculate the number of active IN and to activate an output or something else depending of the numbers of IN? Or any other solution. For example, I want to start 7 machines, and for each machine I have a pump that goes at a certain speed. For a machine i have a value for 2 others and so on .... The analog output side is not a problem, with calculating the number of inputs I do not know how to do it. You can randomly start machine 3 with machine 7, for example, do not turn on, which is why I need for any combination of the 7 machines I started, maybe I have 4 out of 7, just do not know which ones will be 4. How can I count the number of active entries? thankx you!

TSX 87 425

$
0
0

Dear All,

I Have line working with TSX 87 425 

I need to know type of software to access to plc program "does it working under (OS/2) and 

can I make it on VM 

type of connection cable how to get it ,

thanks in advanced 


Compile error

$
0
0

Hi Everyone,

 

Learning the ropes of SoMachine V4.2 (coming from Arduino and Ucontrollers), I am using a Sequiental step style program and I am receiving 4 error messages. I'm trying to understand why it won't compile.

 

  1. POU for implicit check is missing. It is recommend to add the POU.
  2. C0032: Cannot convert type "IeSFc.SFCStepType(iesfc,3.4.2.0 (systen))'to type BOOL
  3. "Same error for a different ladder (the output of ladder rung hits the transition step, the transition is a bool which kicks off the beginning of another ladder rung).
  4. C0032: Cannot convert type BOOL to "IeSFc.SFCStepType(iesfc,3.4.2.0 (systen))

Are these two different "data" types?

 

Thanks in advance!

Compile error

$
0
0

Hi Everyone,

Learning the ropes of SoMachine V4.2 (coming from Arduino and Ucontrollers), I am using a Sequiental step style program and I am receiving 4 error messages. I'm trying to understand why it won't compile.

 

  1. POU for implicit check is missing. It is recommend to add the POU.
  2. C0032: Cannot convert type "IeSFc.SFCStepType(iesfc,3.4.2.0 (systen))'to type BOOL
  3. "Same error for a different ladder (the output of ladder rung hits the transition step, the transition is a bool which kicks off the beginning of another ladder rung).
  4. C0032: Cannot convert type BOOL to "IeSFc.SFCStepType(iesfc,3.4.2.0 (systen))

Are these two different "data" types?

 

Thanks in advance!

Modicon TSX P57102 Macdermid FlexLight 5280

$
0
0

Hi I am looking for some help. I'm not technical at all with this and came across this forum for plcs. I run a small business in Missouri and we purchased some equipment a few months back. It's a Macdermid Flexlight 5280 to make printing plates with. In it is a Modicon TSX P57102. During the move it lost its memory. We have disks etc to run a back up but I can't access the machine. I'm just not technical enough. We have reached out to everyone and am still coming to a dead end. Just looking for some help.  I can pass along any info needed just don't know what is needed.  Thanks in advance . 

m221 somachine basic power on to set bit off

$
0
0

Hello. I have a m221 and use basic somaks to programe it. The problem is the following. I use %mw0:x0 to allocate a button on off HMI, If on the HMI press the button to set him "ON",and pull the voltage from HMI and M221, when power supply, the button is still "ON", it does not return to an initial state "OFF". HMI i use a Weintek 8070 programmed with easybuilder pro. How can I do that when I power the HMI and M221, the button to be OFF, even if the voltage was off when the button was ON. Thank you.

pompa 1.png

pompa 2.png

PL7-2 installing

$
0
0
Hi Everybody. I have problem with install a PL7-2 software for programming TSX17 First installing a user interface from floppy is OK When I start installing a program then apperars error Fatal Error :214 C:\XDOSSYS\HLP\*.* What is the reason for this? OP system is Win98 and laptop is PII IBM ThinkPad I tryed also Win95 and other PC´s - result is same. I did everything like in this help manual Greetings Pertti PL7_2_V51.doc

Vijeo XD V2.4, somachine V4.2, M241 PLC AND HMISTO735

$
0
0

Hello, 
I am try to connecting HMISTO735 with M241 PLC. The Magelis HMISTO735 software designation is Vijeo XD. Maybe somebody have experients how need connect HMI with PLC by somachine and vijeo xd software?

M241 not seeing CanOpen VW3A3608

$
0
0

I have an application with a VW3A3608 communicating with a M241CEC24R. I've connected the two together with a CAT5 cable and connected CAN_H to Pin1, CAN_L to Pin 2 and CAN_Gnd to Pin3. The rest of the Pins unconnected. Running SoMachine 4.3 with all the updates. Terminated on the PLC with the switch and at the Drive with the RJ45 proper terminating jack. The ATV320 is setup as Fr1=CanOpen and Communications is setup with the proper node address. Any help appreciated.

 


KepServerEX and Modicon M211 Modbus TCP Problem

$
0
0

hi All,

I am using KepServer EX V4.0 to read and write network objects ( %IWMx & %QWMx) of M221 PLC via Mobus TCP but it does not succeed although quality show good on OPC client meaning value of registers was changed in OPC client but it did not change in PLC program and vice versa. The unit ID of M221 is 247 and same for device ID in KepSever. Please see attached screenshots of configuration and advise.

Thanks so much in advance

Kind regards,

Steven

Kepserver-Device Properties.PNG

M221-Modbus mapping.PNG

M221-Ethernet IP.PNG

OPC-Client.PNG

tsxcusb485+tsxcrjmd25 cable connection problem with Modicon Premium PLC

$
0
0
I am experiencing a  problem. I have purchased tsxcusb485+tsxcrjmd25 cable in order to communicate with a Modicon Premium TSXP57103 PLC. This is the cable according to Schneider Electric formal site for that communication.
I have installed PL7 Pro in Windows 7 32 bit and Unitelway driver. The settings for the cable are 2(Ter Direct) and No Polarization. I can see in the device manager the TSXCUSB485(com 3) in the ports section.  Do I also have to see the PLC in the Device Manager?
I have used Driver Manager, configured Unitelway Driver to Com3 but in X-Way connectivity test it never connects to the PLC. 
I have tried changing Com ports, I have installed every possible driver I could find in the web but without any result. I have also installed the PLC USB driver without any result. 
I have also installed PL7 pro in windows 10 , but the result is the same. 
I have searched the net, I have found a lot of information, and almost all they present this communication as something trivial. And the steps to follow are simple. However without any luck.
Do I have to use Windows XP?
Can anyone help me resolve this issue? 
Thanks in advance.

TSX P57102

$
0
0

Hi, I posted a previous message regarding a TSX 102 but I got the plc number wrong. It should be TSX P57102. The rest of the message is the same. Can anybody help please.

schneider TSX P57203 SCADA + Monitor Pro

$
0
0

Hello. Please tell me, I have a device that works schneider TSX P57203 SCADA Works on a program Monitor Pro Schneider Electric, But the program Monitor Pro  has recently appeared on some problems And it does not work well, I wanted to reinstall the program Monitor Pro and change some of the controls on the control screen SCADA, but I could not install the program despite all attempts. please help.

Concept 2.1 XL and TSX Compact E984

$
0
0

I’m new to PLCs and having an issue.

I have Concept 2.1 XL, a project folder from the OEM (no .aac file),  and a TSX Compact PC-E984-265 in a PCI/Wedeco ozone generator.

We are doing a hardware upgrade to the machine that requires some logic changes in the PLC.

I load the project and when I connect to the PLC first I get: “LPC Service on PUnit failed! Error id: OLI-21709.” After I dismiss that I get: “Lader logic mismatch checksums are different.” (Currently testing on a blank PLC do to similar errors on the production unit and don’t want to totally kill the production PLC while fiddling around) The messages window has: “update PLC or PUnit (-1644)” The PLC has version 1.05 software on it.

From all of the poking around I have done it seems I may be missing a .bin file in my \Concept\DAT\ directory. I have: M1exec, Q186v214, Q486v212, Q586v100, and Strip_m1 .bin files. Or, I need to update the firmware in the PLC. But, I can’t figure out which I need or where to go to get it.

Any pointers are most welcome!