Master & Slave configuration between 2 PLC Twido TWDLCAE40DRF

$
0
0

I need solution for master & slave configuration between 2 PLC Twido TWDLCAE40DRF.

My final project is about a system for filling drink on a cup and do the packaging. the component of the project is the filling system (dropping cup, filling water, pressing the seal) and the packing (packing into a box and sealing the box). This project is using 2 PLC Twido TWDLCAE40DRF. My problem is how to configure one of them as the master and the other as the slave. I've read the manual book but it's hard to understand the instruction. if anyone can give a simplify explaination to me please reply this post or you can reach me at mail: tatangprayoga11@gmail.com

 


M580 password encryption

$
0
0

Good morning everybody,

 

I am working on a project using Schneider M580 PLC. The PLC is connected on an Ethernet Switch and all connection from Unity to the PLC is made through the Ethernet network. My customer is asking me to demonstrate that the PLC connexion password traveling on the network is encrypted. Would any one of you be able to guide me to a document where this is explicitely said. I have being searching Unity help file, the M580 reference Manual, The M580 Planning guide, Modicon cybersecurity reference manual, etc and all I could find is a mention that password is encrypted in the programm file. Close but not what I need to prove to the customer.

 

Kind regards,

ASCII manager configuration somachine 4.2 RS232

$
0
0

Hello,

I try send data in the serial line 1. I wrote simple code which you can see in the picture, I try send data to external equipment and got communication error code 14=0xE. In the somachine modbus and ascii manual is wrote "The length is incorrect." I don't know which length is incorrect. Maybe somebody know how solve this problem?

error_communication1.jpg

ASCII_configuration.jpg

comerror.jpg

error 1850 when trying to activate web gate

$
0
0

hey,

I'm making a program with vijeo designer with a HMIGTO5310 and with somachine basic and a TM221C16R. At the moment i don't have my TM221C16R yet but i'm able to run the program in simulation on my pc and connecting the hmi to it. I'm able to control everything on my hmi but the moment i'm trying to activate the webgate, vijeo refuses to download the program to my HMI end gives the error " error 1850: [target] [target1] secondary drive full or not found. check the data file location setting.". Is this because it isn't connected to a real PLc but a simulation of it or is it because something else?

send only hex number via rs232 serial line 1 M241

$
0
0

hello,

Maybe somebody know how need send only hex numbers via rs232 in the external device? I tried to use SEND_RECV_MSG function block, but unsuccessful, because send ASCII code. Need send 16#AE number, but I don't have any idea how need do it. I am waiting your advice.

backup on a HMI PROFACE GC 4401

$
0
0

GOOD MORNING ,please can you give the procedure which can explain me how I can realize a backup on a HMI proface  GC 4401with USB key.

Add array somachine

$
0
0

Hello,

Maybe somebody give to me advice, how simple add data of array from bufferrr[1] to bufferrr[24]. I try this, but it is long code

 

array.jpg

Momentum RS485 Read

$
0
0

Morning Guys,

For my latest project I need to read a gas sensor via 485 from a Momentum PLC. I've been through the help files, but they seem to only raise more questions than they answer, they only seem to reference PLC -> PLC comms.

I've had a play with the 'MBP_MSTR' & 'OUT_IN_MBUS' function blocks, but i can't seem to get anywhere,

Has anyone got any examples of reading in data via 485, or can anyone lead me in the right direction?


Communicate from M580 to Allan Bradley Powerflex 753

$
0
0

Have anyone tried to communicate from Schneider M340 til Allan Bradley Powerflex 753 over Ethernet/IP With help of EDS file provided from Rockwell?

The read is going ok. But it seems like I can not Write to converter.

Schneider HMIGTO5310

$
0
0

I'm struggling to get numeric display to show numbers above 65536 on HMIGTO5310 

In the HELP INTEGRAL 

I have followed the DINT   Bin   2's complement   32 bit input which should allow numbers -2147483648~+2147483647 range, how ever when the number reaches 65536 it stops and continues from zero counting up until the count stops. Then when counting down it counts from the stopped number until it reaches zero and the continue counting down from 65536.

I have tried putting min = -2147483648 and max = +2147483647, but this doesn't work either?

I can display any number up to 65536

My HMI software is v6.2.189

I can display any number above 65536 on runtime screen on the schneider(telemecanique)  PLC7 premium which the HMI is connected to?

Can any body help me with this problem?

regards

Tony   

dataloger M241 PLC

$
0
0

Hello,

I have try to write data to file, but I got error and I don't know how solve it this problem My code and error I attached photo. Maybe you could give to me advice how solve it

datalogger.jpg

datalogger_write.jpg

error.jpg

meniu.jpg

writeee.jpg

Telemecanique SR1 B201BD Programming

$
0
0

I have a Telemecanique SR1 B201BD smart relay that I would like to program.  I have downloaded and installed ZelioSoft2 V5.1.  I will be connecting my laptop up to it via the SR1 CBL01 serial cable.  I am currently running Windows 10 as my host PC, but have VMs all the way back to XP in 32 and 64 bit varieties.

 

Now when I try to communicate or transfer, I get an error "DC46_10" which describes possible solutions such as com port already in use.

 

I have search around and have found two conflicting answers about ZelioSoft2 and its ability to program SR1 smart relays.  On Schneider's website it says ZelioSoft2 can program SR2/SR3 smart relays, but other forums like this one say it can also program SR1.

 

If it can not program SR1 smart relays, where do I find ZelioSoft1 or whatever programming software is required to program this smart relay.

M241 and NTP server

$
0
0

Hello,

Could somebody say to me Is it possible M241 plc Synchronization with NTP server? If yes, how need do it?

 

CANOpen comunication

$
0
0

I started working with Schineider PLC and I have to communicate CANOpen with another device, can anyone tell how do I configure this device.

It isn't a device from Schneider.

 

Thanks 

PL7-2 installing

$
0
0
Hi Everybody. I have problem with install a PL7-2 software for programming TSX17 First installing a user interface from floppy is OK When I start installing a program then apperars error Fatal Error :214 C:\XDOSSYS\HLP\*.* What is the reason for this? OP system is Win98 and laptop is PII IBM ThinkPad I tryed also Win95 and other PC´s - result is same. I did everything like in this help manual Greetings Pertti PL7_2_V51.doc

controlling altivar 71 by modicon m340

$
0
0

i have altivar 71 speed drive without graphic display, and plc modicon m340 with only ddi and ddo modules and no communication module, i want to control the altivar 71 from plc through serial modbus but i don't know how to do so is there any book i can read or place to get information from ? all catalogues only explaining the  graphic display which i don't have, i only need to conrol the speed and start stop function no other parameters!!

set coil on monday at 02:00 pm

$
0
0
Hello everyone

've need help for my simple program. 

i've a magelis scu655 and i want set a coil on monday at 02:00 pm but i've problem with time !!!!

this sample don't work

can you help me ???? thanks

 

2018-02-02_122444.jpg

Water mixing bench

$
0
0

Good day all!

I am a 4th year mech engineering student. My final project is a water mixing bench where hot water from a hot reservoir supplies a heat exchanger which cools the water with air and the cool water flows back on the return line.

The hot water line consists of a centrifugal pump then a three-way actuated valve with allowing cold water to flow from the return line to lower the temperature. The hot water line then passes through a second centrifugal pump and another three -way actuated valve allowing cold water from the return line to mix with the hot line influencing the flow rate.

Basically the first valve is used for temperature control and the second valve is used for flow control.

The temperature can only be lowered due to the cold water.

Pumps operate at max set speed and do not have a vsd.

The temperature sensor reading is taken at the hot water outlet to the heat exchanger (desired set temperature) and another at the cold water outlet from the heat exchanger.

A pid controlls both actuators as said before - first actuator for temperature control and the second for flow rate control.

I am new to pid control and not sure what approach to take, because in the past, the pid controllers clashed. 

The temperature sensors and actuators are programmed into the plc already and all that needs to be done is the transfer function and constants for the controllers.

It is a Siemens Simatic S7-1200

If anyone could give me a basis on where to start and how I should go about calculating the constants for both controllers, or if the plc can do it for you?

Altivar 71 Command word

$
0
0

I connected between Altivar 71 VSD drive and Modicon M340 PLC through MODBUS RTU RS485 and the communication is ok, now i want write  a command word using Write_var function to control the VSD but I find very confusing.

first : it's written in cataloug that bits from 0 to 15 can be assigned to commands , is that done from HMI? i  can't find anywhere on HMI.

second : in the function (both read and write) obj element can be int or bool bit but the EMIS element  in 'write_var' function (data going to VSD registers) only accepted if it's array of int not bool so i can't trigger the bits i want !!

third : like the picture the VSD showing it's in NST mode and it says that it won't start until hex value of 6 written to command word but the catalogue says that only bit 0 is assigned(to forword command) and other 15 bits are free for user to assign and 6 in hex (0110) bit 1 and bit 2 still not assigned to any thing  !!

i hope anyone could help 

3.PNG

4.PNG

5.PNG

Modicon 484 reprogramming

$
0
0

Hello we recently purchased an offset printing machine from a closed print shop which is controlled by a Modicon Gould 484 plc.  Due to the machine being disconnected from power for quite a bit the batteries had drained and the plc has lost its memory.  However along with the documentation of the machine we received a backup program for the 484 on a floppy disk in sta format.  I would like to know if anyone can help and advise me on how to reprogramme the 484 and also about the necessary software and cables required.  We have checked the machine and all systems are functional 