Schneider tm221 plc

$
0
0

Hello,

 

Any one  have idea how to read and write variable for Schneider tm221 plc with Modbus function codes 3,6,16.

I attached file for power supply communicator with registers, I need to adjust power supply from 25% up to 100. Please need help.

Best regards,

 

Chyngyz

 

Modbus OPERATING INSTRUCTIONS.pdf


Citect Scada and Micrologix 1100

$
0
0

Hello everyone!

I would like to connect a Micrologix 1100 with Citect 7.5 via ABMLXEIP (updated to latest version). I tried everything and it is still not working.
The Citect and the PLC are on the same subnet and the ping works fine. All the configuration is done as the manual says (I attach the pictures). I have one NIC card and is connected to the PLC. The role is setted to “Server and Control Client”.

The kernel has this error:
[ERROR] [CORE] [0x07fc] [IOServer] [(GLOBAL)] [ErrorLog()][errlog.cpp] [266 ] Error: Channel offline, cannot talk CINIT 0015 PORT1_BOARD1 IODev_1100 Error_in_CMD-2 16 Generic 000021 Driver 00000020 (0x00000014)

Any help would be much appreciated!


Thanks,
Gustavo.

configuracionCitect.jpg

Modbus TCP on Optical Fiber with M340

$
0
0

Hello,

I'd like to ask for a technical confirmation on using MODBUS TCP in a M340 + Fiber Converter Card (BMXNRP0200C) or Switch (ADAM 6521) + Fiber Optic patch cords and cable topology to communicate with a SCADA system.

The main objective is to provide a fiber optic connection point inside a control panel because it is located in a area prone to electrical interference. The protocol to be used would be MODBUS TCP. We have two simple topologies in mind but we are not sure if they are feasible. So i'm asking for a little support about it.

Considering the attached simplified topologies (Drawing1.jpg), am I able to use MODBUS TCP to communicate a M340 with a SCADA workstation with no problem? I'm not sure if the protocol allows this kind of change on the physical medium like if it was pure Ethernet.

 

 

Drawing1.jpg

Schneider sr3 b262bd syntax

$
0
0

Hi,

I've never worked on this range of PLC before, and am trying to make sense of the program currently loaded.

Using the manual I have most of it worked out, but there is one aspect I can't find reference to at all. Why are some of the timer references in inverse text? e.g.

M1----T1----T3-----t4----------------[M2

Thanks in advance

XBTN410 with M200C16R

$
0
0

I have a small HMI with tage number (XBTN410)
 and I need to connect it with (m200c16r plc)
by using RS485 what is the name of the cable to make this connection and what is the pin connection between HMI and PLC
 

Configuration LXM

$
0
0

 Hello. Does anyone know how LXM60d is configured?I need to set his IP.

Connec HMI Proface ( GP2500) with PLC Delta ( DVP-ES2) , Please help me ?

$
0
0

Dear All,

At the moment, I have project with PLC Delta and HMI Proface. I design HMI GP2500 by GP-PRO/PBIII ( V7.0). I see in List Device PLC of Software  not support PLC Delta. 

Can you tell me how do you connect or Software HMI Proface ( Gp2500) support PLC Delta ?

Thanks you very much.

Write single coil to Modicon TM218 Plc Using Easymodbus

$
0
0

Hello, I am using Easymodbus library to Communicate with Modicon TM218 PLC. Reading and Writing of Holding Registers working fine. But coming to writing of single bit in data register i am facing Problem. Need to know how we find coil address of a data register. e.g I have to write bit 1 to MW70.1 address. How we do that. Right now i am reading complete MW70 Register and Manipulating it using bit manipulation techniques and again Writing using Write single Register Function. It's working but some times because of reading problem it writes some garbage values. At that time complete system effecting. 

 

Please provide me any solution.

Thanks in Advance. 


Citect Scada double confirm pushbutton

$
0
0

Hello,
I need to enter double confirmation on some buttons but I can't figure out how to configure it. Has anyone ever configured double confirmation on button?
(citect scada)

Thank you

Ethernet IP communication between Schneider M580 and Honeywell ControlEdge UOC.

$
0
0

I want to establish Ethernet IP communication between the following PLC CPUs.

Schneider Electric - BMEP582040

Honeywell - ControlEdge UOC CPU900-CP1.

Where the Schneider must be master and Honeywell must ne adapter.

Let me know if anyone have done this or can help me to do so.

Unity Pro XL v7.0 - Where to find?

$
0
0

I need to back up a program from a Modicon Quantum PLC and according to the information I have been given, this was configured using Unity Pro XL 7.0 .

I cannot find it anywhere (including Schneider Electric website), as it is a fairly old version.

Does anyone know if the installer (ISO) is available anywhere on the web?

A trial version would suffice.

Webvisu tm241 hotkeys button

$
0
0

Good afternoon, I'm trying to configure a shortcut key to trigger a button in webvisu, but it's not working, does anyone have any tips?

Unity Pro XL Get Time of Day

$
0
0

Hi, very new to PLC programming and desperately looking for some help to finish my project!

I need to program a pump to run based on the level in a holding tank. The start/stop set points change throughout the day based on the time. For example, function for the start set point is 1.15372×10^-6 x^6 - 0.000114068 x^5 + 0.00448866 x^4 - 0.0883477 x^3 + 0.877893 x^2 - 3.57417 x + 7.5, where x is in hours. How can I access the PLC time (current hour and minute) so I can use them to calculate the set points? Does Unity Pro XL have pre-defined variables for these?

Twido EXCH & MSG functions

$
0
0
Hi guys, can anybody explain the values that written in the application to retrieve data from modbus slaves through the Ethernet port, i read a little bit from the help of TwidoSuite i understood all the concept of getting the data, the only thing i still don't understand the first 4 raws with that values as it explained in the examples in Hex, and why does it changes all the time. and how can i determine from which addresses i would like to get the data from the slave? please see attached example of code as described in help. Thanks in advance, Best Regards, Greg.

Reading Multiple Slaves using Modbus Function Codes 3/4

$
0
0

I can read registers of one soft starter, I tried to read registers of four soft starters using a M221 PLC but I can't! Please anyone explain me on these MSG1/2 to read all the soft starters' registers using a master PLC (M221)

Thanks


Modbus Function Codes 3/4

$
0
0

I am new to MRPLC forum, how can I be selective to registers which I want to read instead of reading all consecutive registers from a single slave device. Attached is how I wrote to read 11 consecutive registers from a soft starter using Function Code3.

RS485 Communication.png

PTO Axis not ready

$
0
0

Hello!

I am trying to implement afunction block in order to put a stepper motor working on open loop.

Despite everything i tried i always have an error messagem saying the axis is not ready.

Can somebody explain to me how to solve this problem.

Thanks in advance.

Sorting Memory Words

$
0
0

Hey Guys,

Modicon M221 PLC, programming with Machine Expert.

I have a project that I must create shifts for heating elements, requiring that some heating elements, those who were on for the longest period, do not turn on in the next shift.

I'm looking for a sorting mechanism to determine what %MW (6 words of 8 total) have the largest value.

I would like an array of 8 words, sort them, and retrieve the highest 6 or highest 4 or highest 2.

 

Thanks.

 

ZelioSoft ladder language

$
0
0

Hi all,

 

I'm quite new to this all but here goes.

I have a SR2 system that manages a hydronic heating system, coordinates demand and valves, etc

I was wondering if there is a function in ZelioSoft that would allow me to measure how much time a valve is open (how much time a command is active). So after the heating season, I could see where the demand was in the system (in hours).

So far, the function I've seen do not allow this. (Counter will activate when there is a demand, but will not account for time). 

Anybody knows if this is actually feasible ?

Thank you

 

TSX PSY1610

$
0
0

Hey Guys,

Hope you are doing well! 

Need all your experience support, to recover my existing project.

As I'm at power plant project, we had PLC system with Vijeo Citect 7.3 licensed.

As I'm newbie into this automation, doing my best to complete the project.

AS I need you support to get resolved my project and my query.

Query 1)Unable to get meter reading through plc to scada.

Query 2)PLC gets and err blink and its not communicating as two plc available, one working perfect and other gives err blink after reset.

Kindly help me out 