Step by step hmi and printer setup and report printing

Hi, Please help me to setup Schneider hmi and printer. And report printing.

View Article


Zeliosoft power outage issue

Hello all,    just an amateur here with a zelio issue. very basic cascading program ( ladder ) with 3 inputs , 4 outputs and couple timers. The issue that Im having is that when a power outage is...

View Article


Excel Export of Alarms in Citect SCADA 7.50.

Hello, I am new to Scada Programming. I am using Citect scada V7.50. I have completed whole project, but I am unable to generate Excel report for Alarms generated during run time. Please help me for...

View Article

Image may be NSFW.
Clik here to view.

M580 DTM Browser

Hi all, I'm having an issue with EcoStructure Control Expert where when using DTM browser I try to connect but I get a message "No Ethernet/IP device at specified address...." My issue is that I had a...

View Article

Image may be NSFW.
Clik here to view.

''INVISIBLE'' buttons in PROFACE

Hello,  I am doing PROFACE HMI touch screen projects, and I recently came up with an problem. I am using GP-PRO EX software to program and then later I would transfer the project to my PROFACE...

View Article


Somachine ethernet port

Hello, i need more information about possibility to connect a LC28 CPU with OpenVPN with Mikrotik. I checked tecnical information about TCP port and i wrote the NAT routes on the Mikrotik. I saw a...

View Article

Advantys STB to Omron

I am trying to connect an Advantys RIO island with a STBNIC2212 ethernet/IP to a Omron CJ2 PLC. I need an EDS-file for the Omron Network Configurator but the Advantys Configuration Software will only...

View Article

Image may be NSFW.
Clik here to view.

Modicon TSX Momentum 170ISP00100 Weighing Module

Hi. I need to troubleshoot a Modicon TSX Momentum 170ISP00100 Weighing Module. This hardware was discontinued by Modicon a few years ago. Does anybody have the configuration/runtime software for this...

View Article


Schneider tm221 plc

Hello,   Any one  have idea how to read and write variable for Schneider tm221 plc with Modbus function codes 3,6,16. I attached file for power supply communicator with registers, I need to adjust...

View Article


Moore APACS DCS - Upgrade Experiences

Facility where I recently started working has several "ancient" Moore APACS DCS systems.  The resident guru/expert has announced that after 40+ years with the company he'll retire next year.  The...

View Article

HMI Data transfer to PLC

Hi there! I'm trying to communicate HMIS5T HMI with a Modicon Micro TSX3722001 PLC. The communication is OK, but whenever I try to enter some data into a numeric display I get an error that says...

View Article

How to read PacDrive / SoMachine Motion program scan / execution time?

SoMachine Motion Logic Builder V4.31. Can anyone guide me on how to read the execution time of the STL logic in my application? Thanks.

View Article

TSX AEY414 Problem

Dear All, TSX AEY414 was installed on a machine  and was working fine. suddenly module becomes faulty and its ERR LED tuned ON we replace the new same module and the new module was showing the same...

View Article


Unity Pro - M580 and Tesys-T over 2-wire Modbus

Does anyone out there have any experience with setting up communications between a Unity processor (I'm using an M580) and numerous Tesys-T LTM R Modbus controllers over 2-wire Modbus?  I am stuck and...

View Article

M221 PLC with Kinco GL070E HMI

Hey! Whats up guys ;) I'm a student and I have been saving up money for PLC for quite a while now, I was recommended to use Schneider M221 TM221CE24R PLC. after buying it I looked online for some HMI...

View Article


SoMachine control Powerflex 525 over Ethernet/IP

Hi Guys I'm using the Control_ATV block to control all the Altivar drives, but now I have a Powerflex 525 installed into the system (M241 PLC). Who has successfully controlled a Powerflex over...

View Article

Modicon M241 PWM problem

Hello everyone, I am trying to program a PWM output on Machine expert 2.0. After compiling, I am getting this error: C0138: No matching FB_init method found for instantiation of PWM_M241 Does anyone...

View Article


MOdicon M221 into Citect SCADA 7.2

Hello, I need to replace an obsolete twido PLC to Modicon TM2221ME32TK and in the process would like to get the variables back into Citect SACDA V7.2 I have been reading up on REad_var and write_var...

View Article

VFD ATV610 Parameters Commissioning

Hi Folks, I want to do commissioning on VFD drive ATV610D15N4. Is there any software that I can retrieve parameters like Somove, Powersuite or PC Soft?

View Article

Modicon TSX - %S4,%S5,%S6,%S7

Hi there Could anyone explain to me how these status bits work please? Fo instance %S6 is a 1 second pulse and %S7 a 1 minute pulse.  Do these just give a rising edge pulse after 1 second and 1...

View Article